For Easy Printing, Use Buttons Below

|
AECO > Oilfield Explosives > Dynawell > Specifications 
|
|
Technical
Data Sheet
|
Quality Control Test
|
Function
test
|
|
|
Temp
|
Temp
& Pressure
|
Temp
|
Temp &
Pressure
|
Temp
|
Temp
& Pressure
|
|
Hexacord PT 150
|
302°F/1h
|
302°F/14,400
psi/1h
|
320°F/1h
|
311°F/15,950 psi/1h
|
356°F/1h
|
320°F/15,950
psi/1h
|
|
Octocord PT 165
|
330°F/1h
|
330°F/14,400
psi/1h
|
338°F/1h
|
338°F/15,950 psi/1h
|
420°F/1h
295°F/209h
|
Not
Tested
|
|
Octocord PT 185
|
401°F/1h
|
365°F/14,400
psi/1h
|
410°F/1h
|
374°F/15,950 psi/1h
|
410°F/1.5h
|
374°F/21,750
psi/1h
|
|
Octoslim PT 185
|
401°F/1h
|
365°F/14,400
psi/1h
|
410°F/1h
|
374°F/15,950 psi/1h
|
410°F/1.5h
|
374°F/21,750
psi/1h
|
|
HNS Cord PT 250
|
482°F/1h
446°F/200h
|
392°F/20,160
psi/1h
|
491°F/1h
|
410°F/21,750psi/1h
|
500°F/1h
|
280°F/29,000
psi/8h
|
|
HNS Slim PT 250
|
482°F/1h
446°F/200h
|
392°F/20,160
psi/1h
|
491°F/1h
|
410°F/21,750psi/1h
|
500°F/1h
|
Not
Tested
|
| |
|
|
|
|
|
|
|
Hexacord T 150
|
347°F/1h
320°F/24h
|
Not
recommended
|
356°F/1h
|
Not Tested
|
374°F/1h
221°F/207h
|
Not
Tested
|
|
Octocord T 190
|
374°F
/1h 302°F /200h
|
Not
recommended
|
383°F/1h
|
Not Tested
|
410°F/1h
|
Not
Tested
|
|
Octoslim T 190
|
374°F
/1h 302°F /200h
|
Not
recommended
|
383°F/1h
|
Not Tested
|
410°F/1h
|
Not
Tested
|
| |
|
|
|
|
|
|
|
Dynawell Z-480
|
302°F/1h
|
302°F/14,400
psi/1h, with PT 185 detcord 338°F/16,000 psi/1h
|
Not Tested
|
302°F/14,400 psi/1h,
with PT 185 detcord 338°F/16,000 psi/1h
|
Not
Tested
|
Not
Tested
|
|
Dynawell 1018
|
356°F/2h
|
356°F/14,400
psi/2h 374°F/15,800 psi/1h
|
Not Tested
|
356°F/14,400 psi/2h
374°F/15,800 psi/1h
|
Not
Tested
|
Not
Tested
|
|
Dynawell 1019s
|
374°F/2h
|
374°F/14,400
psi/1h
|
Not Tested
|
374°F/14,400 psi/1h
|
Not
Tested
|
Not
Tested
|
Dynawell 1423
|
446°F/1h
|
446°F/21,000
psi/1h
|
Not Tested
|
446°F/21,000
psi/1h
|
Not
Tested
|
Not
Tested
|
| |
|
|
|
|
|
|
|
Dynawell 0015 FD
|
302°F/1h
|
not
applicable
|
302°F/1h
|
not applicable
|
311°F/0.5h
|
not
applicable
|
|
Dynawell 0026 FD
|
500°F/1h
|
not
applicable
|
500°F/1h
|
not applicable
|
509°F/0.5h
|
not
applicable
|
|
Technical
Date Sheet
|
Max.
temp & pressure that DN recommends to use these products at
according to their respective Technical Data Sheets.
|
|
Quality Control Test
|
Max. temp &
pressure that DN test these products for as part of the
production QC procedures.
|
|
Function
Test
|
Max.
temp & pressure that DN has exposed these products to and these
products did function under laboratory conditions.
|
|
|